PANASONIC DMC-TZ1.pdf

(2962 KB) Pobierz
dsc0603011ce.fm
ORDER NO. DSC0603011CE
B26
Digital Camera
DMC-TZ1PP
DMC-TZ1PL
DMC-TZ1EB
DMC-TZ1EE
DMC-TZ1EF
DMC-TZ1EG
DMC-TZ1EGM
DMC-TZ1GC
DMC-TZ1GK
DMC-TZ1GN
DMC-TZ1GT
DMC-TZ1SG
Vol. 1
Colour
(S)...........Silver Type
(K)...........Black Type
(A)...........Blue Type (except PL/GN/GT)
© 2006 Matsushita Electric Industrial Co., Ltd. All
rights reserved. Unauthorized copying and distribu-
tion is a violation of law.
171721430.003.png 171721430.004.png
TABLE OF CONTENTS
PAGE
PAGE
1 Safety Precaution ------------------------------------------------- 3
1.1. General Guidelines ----------------------------------------3
1.2. Leakage Current Cold Check ---------------------------3
1.3. Leakage Current Hot Check (See Figure 1.) --------3
1.4. How to Discharge the Capacitor on Power/Top
PCB------------------------------------------------------------4
2Warning -------------------------------------------------------------- 5
2.1. Prevention of Electro Static Discharge (ESD)
to ElectrostaticallySensitive (ES) Devices -----------5
2.2. How to Recycle the Lithium Ion Battery (U.S.
Only)-----------------------------------------------------------5
2.3. Caution for AC Cord(For EB/GC/SG) -----------------6
2.4. How to Replace the Lithium Battery -------------------7
3 Service Navigation ------------------------------------------------ 9
3.1. Introduction --------------------------------------------------9
3.2. General Description About Lead Free Solder
(PbF) ----------------------------------------------------------9
3.3. Important Notice 1:(Other than U.S.A. and
Canadian Market) ------------------------------------------9
3.4. How to Define the Model Suffix (NTSC or PAL
model)------------------------------------------------------- 10
4 Specifications ---------------------------------------------------- 12
5 Location of Controls and Components ------------------ 13
6 Service Mode ----------------------------------------------------- 14
6.1. Error Code Memory Function ------------------------- 14
6.2. Confirmation of Firmware Version ------------------- 17
7 Service Fixture & Tools --------------------------------------- 18
7.1. Service Fixture and Tools ------------------------------ 18
7.2. When Replacing the Main PCB ---------------------- 19
7.3. Service Position ------------------------------------------ 19
8 Disassembly and Assembly Instructions --------------- 20
8.1. Disassembly Flow Chart-------------------------------- 20
8.2. PCB Location---------------------------------------------- 20
8.3. Disassembly Procedure -------------------------------- 21
8.4. Disassembly Procedure for the Lens --------------- 27
8.5. Assembly Procedure for the Lens ------------------- 29
8.6. Removal of the CCD Unit ------------------------------ 30
9 Measurements and Adjustments -------------------------- 31
9.1. Matrix Chart for Replaced Part and Necessary
Adjustment ------------------------------------------------- 31
10 Maintenace -------------------------------------------------------- 32
10.1. Cleaning Lens and LCD Panel ----------------------- 32
2
1 Safety Precaution
1.1. General Guidelines
1. IMPORTANT SAFETY NOTICE
There are special components used in this equipment
which are important for safety. These parts are marked by
1.3. Leakage Current Hot Check
(See Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use
an isolation transformer for this check.
2. Connect a 1.5 k Ω , 10 W resistor, in parallel with a 0.15 μ F
capacitor, between each exposed metallic part on the set
and a good earth ground, as shown in Figure 1.
3. Use an AC voltmeter, with 1 k Ω /V or more sensitivity, to
measure the potential across the resistor.
4. Check each exposed metallic part, and measure the volt-
age at each point.
5. Reverse the AC plug in the AC outlet and repeat each of
the above measurements.
6. The potential at any point should not exceed 0.75 V RMS.
A leakage current tester (Simpson Model 229 or equiva-
lent) may be used to make the hot checks, leakage cur-
rent must not exceed 1/2 mA. In case a measurement is
outside of the limits specified, there is a possibility of a
shock hazard, and the equipment should be repaired and
rechecked before it is returned to the customer.
in the Schematic Diagrams, Circuit Board Layout,
Exploded Views and Replacement Parts List. It is essen-
tial that these critical parts should be replaced with manu-
facturer’s specified parts to prevent X-RADIATION,
shock, fire, or other hazards. Do not modify the original
design without permission of manufacturer.
2. An Isolation Transformer should always be used during
the servicing of AC Adaptor whose chassis is not isolated
from the AC power line. Use a transformer of adequate
power rating as this protects the technician from acci-
dents resulting in personal injury from electrical shocks. It
will also protect AC Adaptor from being damaged by acci-
dental shorting that may occur during servicing.
3. When servicing, observe the original lead dress. If a short
circuit is found, replace all parts which have been over-
heated or damaged by the short circuit.
4. After servicing, see to it that all the protective devices
such as insulation barriers, insulation papers shields are
properly installed.
5. After servicing, make the following leakage current
checks to prevent the customer from being exposed to
shock hazards.
1.2. Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the
two prongs on the plug.
2. Measure the resistance value, with an ohmmeter,
between the jumpered AC plug and each exposed metal-
lic cabinet part on the equipment such as screwheads,
connectors, control shafts, etc. When the exposed metal-
lic part has a return path to the chassis, the reading
should be between 1 M Ω and 5.2 M Ω . When the exposed
metal does not have a return path to the chassis, the
reading must be infinity.
Figure. 1
3
171721430.005.png 171721430.006.png
1.4. How to Discharge the Capacitor on Power/Top PCB
CAUTION:
1. Be sure to discharge the capacitor on POWER/TOP PCB.
2. Be careful of the high voltage circuit on POWER/TOP PCB when servicing.
[Discharging Procedure]
1. Refer to the disassemble procedure and Remove the necessary parts/unit.
2. Put the insulation tube onto the lead part of Resistor (ERG5SJ102:1k Ω /5W).
(an equivalent type of resistor may be used.)
3. Put the resistor between both terminals of capacitor on POWER/TOP PCB for approx. 5 seconds.
4. After discharging confirm that the capacitor voltage is lower than 10V using a voltmeter.
Fig. F1
4
171721430.001.png
2Warning
2.1. Prevention of Electro Static Discharge (ESD) to Electrostatically
Sensitive (ES) Devices
Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called Elec-
trostatically Sensitive (ES) Devices.
The following techniques should be used to help reduce the incidence of component damage caused by electro static discharge
(ESD).
1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any ESD on your
body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging ESD wrist strap,
which should be removed for potential shock reasons prior to applying power to the unit under test.
2. After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface such as alumi-
num foil, to prevent electrostatic charge buildup or exposure of the assembly.
3. Use only a grounded-tip soldering iron to solder or unsolder ES devices.
4. Use only an antistatic solder removal device. Some solder removal devices not classified as "antistatic (ESD protected)" can
generate electrical charge sufficient to damage ES devices.
5. Do not use freon-propelled chemicals. These can generate electrical charges sufficient to damage ES devices.
6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most
replacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminum foil or compara-
ble conductive material).
7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material
to the chassis or circuit assembly into which the device will be installed.
CAUTION :
Be sure no power is applied to the chassis or circuit, and observe all other safety precautions.
8. Minimize bodily motions when handling unpackaged replacement ES devices. (Otherwise harmless motion such as the
brushing together of your clothes fabric or the lifting of your foot from a carpeted floor can generate static electricity (ESD) suf-
ficient to damage an ES device).
2.2. How to Recycle the Lithium Ion Battery (U.S. Only)
5
171721430.002.png
Zgłoś jeśli naruszono regulamin