Thermostat Installation
For installation of thermostats:
301 00 154 (12 volt)
301 00 153 (24 volt)
Note: These instructions illustrate the use of the thermostats sen-
sor to monitor room temperature. Two alternatives are available:
#1) Heaters internal sensor - not available for D8LC.
#2) Remote external sensor- see technical manual for more details.
D5LC heaters may be supplied with this connector connected to the
heaters internal temperature sensor. This must first be disconnected
to allow connection to the thermostat. The D8LC switch harness by
default comes with the wiring for a remote external sensor, this must
be disconnected to allow connection to the thermostat.
Switching on
Turn the on-off switch to the “ON” position. Switch the heaters’ tem-
perature setting by adjusting the temperature control dial to the
desired temperature range.
Step 1
Select a mounting location
which will be representative of
the average temperature of the
area being heated. Avoid
mounting near heater outlets,
windows, doors, electrical appli-
ances or in areas receiving
direct sunlight.
Step 4
Connect the switch harness
wires to the thermostat as
shown on inside sheet.
Please see operators guide for
proper start up and shut down
procedures. See technical manu-
al for more technical information
Step 2
Route the switch harness from
the heater to the thermostat
mounting location.
On/Off switch
Red operating light
Green diagnostic light
Step 3
Mount the thermostat as shown
using proper mounting hardware
and the slots provided on the
thermostat base. Pull the switch
harness through the
thermostat base
access hole.
Mounting slots
Lowest setting - approx. 50°F
Mid setting - approx. 65°F
Highest setting - approx. 85°F
D1LC and D3LC compacts only. On OEM installs the ‘red” &
“green” indicator lights illuminate. On after market installs only the
“Red” light illuminates.
Thermostat base
access hole
D5LC and D8LC heaters only. The green light on the thermostat is
a blink code diagnostic light. It will provide a fault code if a problem
occurs within the heater. Please see corresponding technical manu-
als for activation, interpretation and recommendation.
741813509.003.png 741813509.004.png
Schematics
1 = ground
2 = temperature setting
3 = diagnostic feed (D5LC and D8LC only )
4
5 = power
6 = switch
T = temperature sensor (optional)
Espar
D1LC / D3LC Compact
AIRTRONIC 2& 4
Temperature sensor on
D1LC/D3LC compact
control unit
This wire is “optional”
Temperature sensor on
AIRTRONIC control unit
It is recommended that when using return ducting, not to use this wire. Not using the grey or black wire defaults the heater to use the
temperature sensor on the control unit of the heater.
Use of the grey wire defaults the heater to use the sensor on the thermostat.
The sensor on the control unit provides a more accurate reading of the overall air temperature, whereas the sensor in the thermostat
gives more of a spot reading of the air surrounding the thermostat.
D5LC
D8LC
* discard the remote external sensor wire
(grey sleeve that comes stock with every
D8LC harness) containing the 2 core black
wire and white wire.
Remove grey wire and brown wire from pins
6 & 7 at the round connector.
Remove black wire at pin 12 and insert into
pin 7 at round connector.
741813509.005.png 741813509.006.png 741813509.001.png 741813509.002.png
 