GD90 Personal Cellular Telephone
Order Number: MCUK990801C8
GD90 Personal Cellular Telephone
Handheld Portable
EB-GD90
Specification
900MHz
1800MHz
Frequency range
Tx: 890 - 915 MHz
Rx: 935 - 960 MHz
Tx: 1710 - 1785 MHz
Rx: 1805 - 1880 MHz
Tx/Rx frequency separation
45 MHz
95 MHz
RF channel bandwidth
200 kHz
Number of RF channels
124
374
Speech coding
Full rate/Half rate/Enhanced
Full rate
Full rate/Half rate
Operating temperature
-10°C to +55°C
Type
Class 4 Handheld
Class 1 Handheld
RF Output Power
2 W maximum
1W maximum
Modulation
GMSK (BT = 0.3)
Connection
8 ch/TDMA
Voice digitizing
13 kbps RPE-LTP / 13 kps ACLEP / 5.6 kps CELP / VSLEP
Transmission speed
270.3 kbps
Diversity
Frequency hopping
Signal Reception
Double superheterodyne
Intermediate Frequency
282MHz and 45MHz
Antenna Terminal Impedance
50 W
Antenna VSWR
<2.1 : 1
Dimensions
Height: 118 mm
Width: 42 mm
Depth: 16.5 mm
Volume
84.5 cc
Weight
88 g
Display
Graphical chip on glass liquid crystal, Alphanumeric 16 x 3
characters, 5 icons and 6 x 1 characters
Illumination
Green:
4 LEDs for the LCD
8 LEDs for the keyboards
1 LED Incoming call
Red:
1 LED Charging indicator
Keypad
17 keys, Navigation key
SIM
Plug-in type only
External DC Supply Voltage
3.6V
Battery
3.6V
Standby Battery Life
DRX 9
95 hrs maximum
Conversation Battery Life
PL 7, DTX 50%
200minutes
Unless stated these specifications are with Battery Pack (EB-BSD90) fitted.
Battery life figures are dependent on network conditions.
WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain warnings or
cautions to advise non-technical individuals of potential dangers in attempting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service or repair the product or
products dealt with in this service manual by anyone else could result in serious injury or death.
Issue 1
Revision 0
14757661.001.png 14757661.002.png
This Service Manual is copyright and issued on the strict understanding that it is not to be reproduced, copied, or disclosed to
any third party, either in whole or part, without the prior written consent of Matsushita Communication Industrial UK Ltd.
Every care has been taken to ensure that the contents of this manual give an accurate representation of the equipment.
However, Matsushita Communication Industrial UK Ltd. accepts no responsibility for inaccuracies which may occur and
reserves the right to make changes to specification or design without prior notice.
The information contained in this manual and all rights in any designs disclosed therein, are and remain the exclusive property
of Matsushita Communication Industrial UK Ltd.
Other patents applying to material contained in this publication:
BULL CP8 PATENTS
Comments or correspondence concerning this manual should be addressed to:
Customer Support Department,
Matsushita Communication Industrial UK Ltd.,
Colthrop,Thatcham,
Berkshire. RG19 4ZD.
ENGLAND
© 1999 Matsushita Communication Industrial UK Ltd.
Issue 1
– ii –
MCUK990801C8
Revision 0
Service Manual
WARNINGS AND CAUTIONS
WARNING
The equipment described in this manual contains polarized capacitors utilising liquid electrolyte. These devices are entirely
safe provided that neither a short-circuit nor a reverse polarity connection is made across the capacitor terminals.
FAILURE TO OBSERVE THIS WARNING COULD RESULT IN DAMAGE TO THE EQUIPMENT OR, AT WORST,
POSSIBLE INJURY TO PERSONNEL RESULTING FROM ELECTRIC SHOCK OR THE AFFECTED CAPACITOR
EXPLODING. EXTREME CARE MUST BE EXERCISED AT ALL TIMES WHEN HANDLING THESE DEVICES.
Caution
The equipment described in this manual contains electrostatic sensitive devices (ESDs). Damage can occur to these
devices if the appropriate handling procedure is not adhered to.
ESD Handling precautions
A working area where ESDs may be safely handled without undue risk of damage from electrostatic discharge, must be
available. The area must be equipped as follows:
Working Surfaces - All working surfaces must have a dissipative bench mat, SAFE for use with live equipment, connected via
a 1M2 resistor (usually built into the lead) to a common ground point.
Wrist Strap - A quick release skin contact device with a flexible cord, which has a built in safety resistor of between 5k2 and
1M2 shall be used. The flexible cord must be attached to a dissipative earth point.
Containers - All containers and storage must be of the conductive type.
Batteries
This equipment may contain an internal battery in addition to the external battery packs. These batteries are recyclable and
should be disposed of in accordance with local legislation. They must not be incinerated, or disposed of as ordinary rubbish.
MCUK990801C8
– iii –
Issue 1
Service Manual
Revision 0
14757661.003.png 14757661.004.png
This page is left intentionally blank.
Issue 1
– iv –
MCUK990801C8
Revision 0
Service Manual
 
CONTENTS
1 INTRODUCTION
1.1 Purpose of this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.2 Structure of the Manual . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.3 Servicing Responsibilities . . . . . . . . . . . . . . . . . . . . . . . . 1
2 GENERAL DESCRIPTION
2.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.2 Handportable Main Kit . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3 OPERATING INSTRUCTIONS
3.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.2 LCD Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.3 Location of Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.4 Concept of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.5 Alpha Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.6 Incoming Calling Line Identification (CLI) . . . . . . . . . . . . 7
3.7 Hot Key Dial Source List . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.8 Features Menu Structure . . . . . . . . . . . . . . . . . . . . . . . . 8
3.9 Public Man Machine Interface (MMI) . . . . . . . . . . . . . . . 9
3.10 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.11 Important Error Messages . . . . . . . . . . . . . . . . . . . . . . 12
3.12 Security Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.13 SIM Personalisation . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.14 GSM Services Supported by PC Card . . . . . . . . . . . . . 14
3.15 GSM Network Codes and Names . . . . . . . . . . . . . . . . . 14
3.16 Glossary of Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4 DISASSEMBLY / REASSEMBLY INSTRUCTIONS
4.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.2 Disassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.3 Reassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
5 TECHNICAL SPECIFICATIONS
5.1 Tx Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5.2 Rx Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6 TEST AND MEASUREMENT
6.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
6.2 External Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
6.3 Complete Unit Test Setup . . . . . . . . . . . . . . . . . . . . . . . 32
6.4 Channel Box Test Commands . . . . . . . . . . . . . . . . . . . 36
6.5 Adjustment Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
6.6 I and Q Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
6.7 Lock Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
7 CIRCUIT DIAGRAMS
7.1 Main PCB-RF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
7.2 Main PCB-Logic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
7.3 Keypad PCB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
8 LAYOUT DIAGRAMS
8.1 Main PCB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
8.2 Keypad PCB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
9 REPLACEMENT PARTS LIST
9.1 Case Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
9.2 Sub-Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
9.3 Handheld Replacement Parts List . . . . . . . . . . . . . . . . 59