GAS FURNACES
RGTA- SERIES
Models with Input Rates
from 45,000 to 120,000 BTU/HR
[13.19 to 35.17 kW]
(All Models 90% A.F.U.E.† or Above)
CLASSIC ® 90 PLUS ®
HIGH EFFICIENCY
DOWNFLOW/
HORIZONTAL
GAS FURNACES
The Rheem ® Classic ® 90 Plus ® High Efficiency line of down-
flow/horizontal gas furnaces are designed for utility rooms,
closets, alcoves, attics or crawl spaces. The RGTA is
shipped in the downflow configuration and is easily con-
verted for horizontal left-hand airflow applications.
The design is certified by CSA.
Features
Heat exchanger is constructed of all stainless steel for
maximum corrosion resistance and thermal fatigue
reliability.
Low profile “34 inch” design is lighter and easier to han-
dle and leaves room for optional accessories.
Top electrical connections, left or right gas and conden-
sate drainage connections on downflow models.
Condensate drain for horizontal application provided
standard.
Integrated control board manages all operational func-
tions and provides hookups for humidifier and electronic
air cleaner.
An insulated blower compartment, a slow-opening gas
valve and a specially designed inducer system make it
one of the quietest furnaces on the market today.
Pre-paint galvanized steel cabinet.
Molded permanent filters.
Optional indoor or outdoor combustion air.
Transformer and control fuse protection.
Control board diagnostics.
A variety of cooling coils and plenums designed to use with
the Classic 90 Plus gas furnaces are available as optional
accessories for air conditioning models.
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department
of Energy test procedures.
 
163528118.006.png 163528118.007.png 163528118.008.png 163528118.001.png
CLASSIC 90 PLUS HIGH EFFICIENCY
DOWNFLOW/ HORIZONTAL
GAS FURNACE
INTEGRATED
FURNACE
CONTROL
FUSE PROTECTION
PRESSURE SWITCH
DRAFT INDUCER
GAS VALVE AND
MANIFOLD
PRIMARY AND SECONDARY
HEAT EXCHANGER
DIRECT SPARK IGNITION
REMOTE SENSOR
IN-SHOT BURNERS
STANDARD EQUIPMENT
Completely assembled and wired; heat exchanger; primary: 409 and aluminized
409 stainless steel, secondary: 29-4C stainless steel; induced draft; pressure
switch; redundant main gas control; blower compartment door safety switch;
solid state time on/off blower control; limit controls; manual shut-off valve;
100% safety lock out; cool fan off delay; field selectable heat fan off delay; one
hour automatic retry; power and self-test diagnostics; flame sense current
diagnostics; electronic air cleaner connections; twinning (built-in) features;
humidifier connections; humidifier on/off delay; low speed continuous fan
option; single speed option for heating and cooling applications; transformer;
direct drive, multi-speed blower motor. (Please note: a thermostat is not
included as standard equipment.)
OPTIONAL EQUIPMENT
NOTE: Furnace is not listed for use with fuels other than natural or L.P.
(propane) gas.
All models can be converted by a qualified distributor or local service dealer to
use L.P. (propane) gas without changing burners. Factory approved kits must
be used to convert from natural to L.P. (propane) gas and may be ordered as
optional accessories from a parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
2
Rheem Manufacturing Company
 
163528118.002.png
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE
FROM YOUR RETAILER.
PHYSICAL DATA AND SPECIFICATIONS
DOWNFLOW/ HORIZONTAL MODELS U.S. and Canadian Models
MODEL NUMBERS
RGTA-04EMAES RGTA-06EMAES RGTA-07EMAES RGTA-07EYBGS
RGTA-09EZAJS
RGTA-10EZAJS
RGTA-12ERAJS
120,000 [35.17]
112,000 [32.82]
108,000 [31.65]
INPUT-BTU/HR [kW]
45,000 [13.19]
60,000 [17.58]
75,000 [21.98]
75,000 [21.98]
90,000 [26.38]
105,000 [30.77]
HEATING CAPACITY BTU/HR [kW] 41,000 [12.02]
56,000 [16.41]
69,000 [20.22]
69,000 [20.22]
84,000 [24.62]
97,000 [28.43]
HIGH ALTITUDE INPUT [kW] ➁
40,500 [11.87]
54,000 [15.83]
67,500 [19.78]
67,500 [19.78]
81,000 [23.74]
94,500 [27.70]
HIGH ALTITUDE OUTPUT
CAPACITY [kW]
37,000 [10.84]
50,400 [14.77]
63,000 [18.46]
63,000 [18.46]
75,000 [21.98]
87,500 [25.64]
100,500 [29.45]
BLOWER (D x W) [mm]
11 x 7 [279 x 178] 11 x 7 [279 x 178] 11 x 7 [279 x 178] 12 x 7 [305 x 178] 12 x 11 [305 x 279] 12 x 11 [305 x 279]
11 x 10 [279 x 254]
MOTOR H.P. [W]
SPEEDS-TYPE
1 / 2 [373]-4-PSC 1 / 2 [373]-4-PSC 1 / 2 [373]-4-PSC 3 / 4 [559]-4-PSC 3 / 4 [559]-4-PSC
3 / 4 [559]-4-PSC
3 / 4 [559]-4-PSC
MOTOR FULL LOAD AMPS
6.8
6.8
6.8
9.5
9.5
9.5
9.5
MED-LO
HIGH
HEATING SPEED
MED-LO
MED-LO
MED-HI
MED-LO
MED-LO
MED-LO
COOLING SPEED
HIGH
HIGH
HIGH
HIGH
HIGH
HIGH
HEAT EXT. STATIC PRESSURE
(IN. W.C.) [kPa]
.10 [.025]
.12 [.029]
.12 [.029]
.12 [.029]
.15 [.037]
.20 [.049]
.20 [.049]
RATED EXT. STATIC PRESSURE
(IN. W.C.) [kPa]
.50 [.124]
.50 [.124]
.50 [.124]
.50 [.124]
.50 [.124]
.50 [.124]
.50 [.124]
HEATING CFM @ .2" W.C.
E.S.P. [L/s]
890 [420]
885 [418]
1060 [500]
1375 [649]
1400 [661]
1425 [673]
1565 [739]
COOLING CFM @ .5" W.C.
E.S.P. [L/s]
1220 [576]
1180 [557]
1150 [543]
1625 [767]
1850 [873]
1820 [859]
2040 [963]
TEMPERATURE RISE RANGE
°F [°C]
30-60 [16.7-33.3] 40-70 [22.2-38.9] 45-75 [25-41.7] 35-65 [19.4-36.1] 35-65 [19.4-36.1] 50-80 [27.8-44.4]
50-80 [27.8-44.4]
STANDARD FILTER [mm]
(2) 12" x 20"
[305 x 508]
(2) 12" x 20"
[305 x 508]
(2) 12" x 20"
[305 x 508]
(2) 12" x 20"
[305 x 508]
(2) 12" x 20"
[305 x 508]
(2) 12" x 20"
[305 x 508]
(2) 14" x 20"
[356 x 508]
APPROX. SHIPPING WEIGHT
(LBS.) [kg]
111
117
123
123
148
152
160
AFUE
92.0%
92.4%
92.0%
92.3%
92.4%
92.0%
92.1%
CALIFORNIA SEASONAL
EFFICIENCY
84.9%
86.8%
86.4%
85.7%
86.7%
87.0%
87.4%
NOTES: All models are 115V, 60HZ, 1 ø. Gas connection size for all models is 1 / 2 " [13 mm] N.P.T.
➀ See Conversion Kit Index Form for high altitude derate.
➁ Canadian installations only.
➂ In accordance with D.O.E. test procedures.
MODEL IDENTIFICATION
R
G
T
A
07E
M
A
E
S
Rheem
Gas
Furnace
Downflow/
Horizontal
Condensing
Gas Furnace
Design
Series
Heating Input
Designation
Blower Size
M = 11 x 7
[279 x 178 mm]
R = 11 x 10
[279 x 254 mm]
Z = 12 x 11
[305 x 279 mm]
Y = 12 x 7
[305 x 178 mm]
Variations
A = Std.
B = Wide
Cabinet
Heat/Cool
Designation
E = 1100-1300 CFM
[519-613.5 L/s]
G = 1500-1700 CFM
[707.9-802.3 L/s]
J = 1900-2100 CFM
[896.7-991.1 L/s]
Fuel Code
S = U.S. and
Canadian Natural
Gas
Electric
Ignition
04E
06E
07E
09E
10E
12E
Input
BTU/HR
45,000 [13 kW]
60,000 [17.6 kW]
75,000 [20.5 kW]
90,000 [26.4 kW]
105,000 [30.7 kW]
120,000 [35.2 kW]
[ ] Designates Metric Conversions
GENERAL TERMS OF LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable
period stated, in accordance with the terms of the limited
warranty.
For Complete Details of the Limited Warranty, Including Applicable Terms
and Conditions, See Your Local Installer or Contact the Manufacturer for
a Copy.
Primary and Secondary Heat Exchanger.......Limited Lifetime
*Any Other Part.............................................Five (5) Years
*This five year limited warranty is applicable only to single-phase prod-
ucts installed in residential applications on or after January 1, 2001.
Rheem Manufacturing Company
3
 
163528118.003.png
DOWNFLOW MODELS
MODEL
RGTA-
LEFT
SIDE
MINIMUM CLEARANCE (IN.) [mm]
SHIP
WGTS.
[kg]
A
B
C
D
E
F
RIGHT
SIDE
BACK
TOP
FRONT VENT
04
17 1 / 2 [445] 16 11 / 32 [415] 15 5 / 8 [397] 2 [51] 16 5 / 8 [422]
13 7 / 8 [352]
0
0
0
1 [25]
2 [51]
0
111 [50]
06
17 1 / 2 [445] 16 11 / 32 [415] 15 5 / 8 [397] 2 [51] 16 5 / 8 [422]
13 7 / 8 [352]
0
0
0
1 [25]
2 [51]
0
117 [53]
07EM
17 1 / 2 [445] 16 11 / 32 [415] 15 5 / 8 [397] 2 [51] 16 5 / 8 [422]
13 7 / 8 [352]
0
0
0
1 [25]
2 [51]
0
123 [56]
07EY
21 [533] 19 27 / 32 [504] 19 3 / 16 [486] 2 [51] 20 1 / 8 [511]
17 3 / 8 [441]
0
0
0
1 [25]
2 [51]
0
123 [56]
09
21 [533] 19 27 / 32 [504] 19 3 / 16 [486] 2 [51] 20 1 / 8 [511]
17 3 / 8 [441]
0
0
0
1 [25]
2 [51]
0
148 [67]
10
21 [533] 19 27 / 32 [504] 19 3 / 16 [486] 2 [51] 20 1 / 8 [511]
17 3 / 8 [441]
0
0
0
1 [25]
2 [51]
0
152 [69]
12
24 1 / 2 [622] 23 11 / 32 [593] 22 5 / 8 [575] 2 [51] 23 5 / 8 [600]
20 7 / 8 [530]
0
0
0
1 [25]
2 [51]
0
160 [73]
IMPORTANT NOTE: Horizontal furnace may be installed for horizontal left hand air supply ONLY. The condensate trap provided for horizontal application must be
installed in the field beneath the unit as directed in the furnace Installation & Operating Instructions.
4
Rheem Manufacturing Company
 
163528118.004.png
HORIZONTAL MODELS
IMPORTANT NOTE: Horizontal furnace may be installed for horizontal left hand air supply ONLY. The condensate trap provided for horizontal application must be
installed in the field beneath the unit as directed in the furnace Installation & Operating Instructions.
[ ] Designates Metric Conversions
Rheem Manufacturing Company
5
 
163528118.005.png
Zgłoś jeśli naruszono regulamin