Technical Instructions - HP 1012
HP1012TECH
Technical Instructions
Supplies
Tools
1
CORPORATE
LOS ANGELES, USA
Anhydrous Isopropyl Alcohol
Padding Powder
Soft Lint Free Cloth
Swabs
Toner
BR1240FILLCAP (if the cartridge has no fill plug)
Cartridge pin installation Tool
Long Thin Needle Nose Pliers
Phillips Screwdriver
Small Flat Blade Screwdriver
Diagonal cutters
Bent Extraction Tool
US 1 800 394.9900
Int’l +1 818 837.8100
FAX 1 800 394.9910
Int’l +1 818 838.7047
If the cartridge has no fill plug you’ll need additional tools:
Hole Saw, diameter 7/8, with Arbor
Shaft Collar, Inside Diameter 7/8, set screw type
Drill
ATLANTA, USA
US 1 877 676.4223
Int’l +1 770 516.9488
FAX 1 877 337.7976
Int’l +1 770 516.7794
Photo 1
Step 1
Place the cartridge on the workbench so the
drum shutter is facing up and the drum axle
pin is towards you.
DALLAS, USA
US 1 877 499.4989
Int’l +1 972 840.4989
FAX 1 877 774.1750
Int’l +1 972 840.1750
(See Photo 1)
KANSAS CITY, USA
US 1 913 871.1700
FAX 1 913 888.0626
MIAMI, USA
US 1 800 595.429
Int’l +1 305 594.3396
FAX 1 800 522.8640
Int’l +1 305 594.3309
Photo 2
Step 2
Holding the drum shutter open, use a spring
hook to remove the tension spring located
next to the non gear side of the drum.
NEW YORK, USA
US 1 800 431.7884
Int’l +1 631 345.0121
FAX 1 800 431.8812
Int’l +1 631345.0690
(See Photo 2)
TORONTO, CAN
CAN 1 877 848.0818
Int’l +1 905 712.9501
FAX 1 877 772.6773
Int’l +1 905 712.9502
Photo 3
Step 3
Using a Philips screwdriver remove the two
screws holding the drum bearing hub to the
cartridge. (See Photo 3) Remove the hub.
left side.
BUENOS AIRES, ARG
ARG 0810 444.2656
Int’l +011 4583.5900
FAX +011 4584.3100
MELBOURNE, AUS
AUS 1 800 003. 100
Int’l +62 03 9561.8102
FAX 1 800 004.302
Int’l +62 03 9561-7751
SYDNEY, AUS
AUS 1 800 003.100
Int’l +62 02 9648.2630
FAX 1800 004.302
Int’l +62 02 9548.2635
Photo 4
Step 4
Holding the drum shutter open, lift the drive
gear end of the drum away from the car-
tridge. Rotate the drum counter clock-wise
while pulling the drum off the contact axle
on the opposite side of the cartridge.
MONTEVIDEO,URY
URY 02 902.7206
Int’l +5982 900.8358
FAX +5982 908.3816
JOHANNESBURG, S.A.
S.A. +27 11 974.6155
FAX +27 11 974.3593
(See Photo 4)
E-mail: info@futuregraphicsllc.com
Website:
www.futuregraphicsllc.com
REV. 03/16/06
437613230.044.png 437613230.045.png 437613230.046.png 437613230.047.png 437613230.001.png 437613230.002.png 437613230.003.png 437613230.004.png
 
2
HP 1012 Technical Instructions
Photo 5
Step 5
Using needle nose pliers remove the PCR
from the cartridge. See Photos 5) Clean the
PCR using a mild soap and water.
Photo 6
Step 6
With a bent extraction tool push the cartridge
pin out from the inside of the cartridge. See
Photo # 6.
Photo 7
Photo 8
Step 7
Using diagonal cutters pull the cartridge pins
out from the both sides of the cartridge.
(See Photos 7 and 8)
Photo 9
Step 8
Separate the two sections of the cartridge.
(See Photo 9) Set the toner hopper aside.
Photo 10
Step 9
Remove the drum shutter tension spring.
(See Photo 10)
Need trust-worthy, detailed Technical
Instructions for another engine?
Visit: www.futuregraphicsllc.com
437613230.005.png 437613230.006.png 437613230.007.png 437613230.008.png 437613230.009.png 437613230.010.png 437613230.011.png 437613230.012.png
 
HP 1012 Technical Instructions
3
Photo 11
Step 10
Slide the drum shutter open and lift the
shutter from its cradles.
(See Photo 11)
Step 16
Install the drum bearing hub onto
the side of the cartridge. Install the
two screws that hold the hub in
place.
(See Photo 16)
Photo 12
Step 11
Using a Philips screwdriver remove the two
screws holding the wiper blade.
(See Photo 12) Remove the wiper blade.
Step 12
Clean the waste hopper using dry com-
pressed air or a vacuum. Clean the PCR saddle
contact with alcohol and a swab.
Photo 16
Photo 13
Step 13
Apply padding powder to the used or new
wiper blade. Install the blade onto the waste
hopper and install the two screws that hold
the blade in place. (See Photo 13)
Step 17
Slide the drum shutter over the
waste hopper and place the shut-
ter into its cradles.
(See Photo 17)
Photo 14
Step 14
Apply conductive grease to the PCR contact
(black) saddle. Install the cleaned PCR into the
saddles.
Foto 17
(See Photo 14)
Photo 15
Step 15
Apply padding powder to the drum. While
rotating the drum counter clock-wise, slide
the drum onto the contact axle.
(See Photo 15)
Need trust-worthy, detailed Technical
Instructions for another engine?
Visit: www.futuregraphicsllc.com
437613230.013.png 437613230.014.png 437613230.015.png 437613230.016.png 437613230.017.png 437613230.018.png 437613230.019.png 437613230.020.png 437613230.021.png
4
HP 1012 Technical Instructions
Photo 20
Step 21
Remove the three gears from the side of
the toner hopper, leaving the toner hopper
agitator gear.
Step 18
Reinstall the tension spring onto
the drum shutter.
(See Photo 20)
(See Photo 18)
Photo 18
Photo 21
Step 22
Rotate the cartridge 180°. Remove the screw
holding the contact end cap to the toner
hopper. (See Photo 21) Remove the end cap.
Step 19
Set the waste hopper aside in a
protected area.
Photo 22
Step 23
Lift out the mag roller. Remove the mag roller
bushings from the ends of the roller.
Step 20
Remove the screw holding the
gear end cap to the toner hopper.
(See Photo 19)
Remove the end cap.
(See Photo 22)
Photo 23
Step 24
Clean the mag roller first using dry com-
pressed air or a vacuum. Then clean the roller
using a lint free cloth and a mag roller clean-
er.
Photo 19
Photo 24
Step 25
Remove the two screws holding the doctor
blade to the toner hopper. (See Photo 23)
Remove the white scraper from the end of
the blade, and remove the doctor blade.
Clean the doctor blade using a lint free cloth
and alcohol.
Step 26
Remove the doctor blade sealing end foams
from both sides of the toner hopper.
(See Photo 24)
E-mail: info@futuregraphicsllc.com
Website:
www.futuregraphicsllc.com
437613230.022.png 437613230.023.png 437613230.024.png 437613230.025.png 437613230.026.png 437613230.027.png 437613230.028.png 437613230.029.png 437613230.030.png 437613230.031.png 437613230.032.png 437613230.033.png 437613230.034.png
 
HP 1012 Technical Instructions
5
Photo 25
Step 27
Using a small flat blade screwdriver push
the seal exit port plug out from the hopper.
(See Photo 25)
Step 33
Install a new or a clean used doctor
blade onto the hopper. Install the
two white scrapers on the end of
the doctor blade and install the
two screws that hold the blade in
place. (See Photo 30)
Step 28
Clean the seal area using a swab and alcohol.
Photo 26
Step 29
Remove the backing of the seal and install
the seal onto the toner hopper.
Photo 30
(See Photo 26)
Photo 27
Step 30
Slide the tail of the seal through the seal
exit port and install the plug in the end of the
hopper.
Step 34
Place the mag roller bushing on
the ends of the mag roller, the
white bearing goes on the gear
side and the black bearing goes on
the contact side of the mag roller.
(See Photo 31)
(See Photo 27)
Photo 28
Step 31
Remove the fill plug. Fill the toner hopper
with toner.
(See photo #28)
Reinstall the fill plug.
Photo 31
NOTE: If the cartridge has no fill plug, please
see Appendix A.
Photo 29
Step 32
Install new doctor blade sealing end foams
on both ends of the hopper.
(See Photo 29)
Need trust-worthy, detailed Technical
Instructions for another engine?
Visit: www.futuregraphicsllc.com