AEG General Catalogue (2001).pdf

(5130 KB) Pobierz
Low Voltage
A GE Power Controls Company
General catalogue
962984281.050.png 962984281.061.png 962984281.067.png 962984281.068.png 962984281.001.png 962984281.002.png 962984281.003.png 962984281.004.png 962984281.005.png 962984281.006.png 962984281.007.png 962984281.008.png 962984281.009.png
 
this is a blanc page
Miniature circuit breakers
A
Miniature circuit breakers
Benefits of the new MCB’s
A • 3
The AEG product offer
A • 4
Standards
A • 5
Technical data
A • 6
Short-circuit capacity
A • 7
AC miniature circuit breakers
3 kA
E90N
Char. B
2-40A
A • 8
Char. C
2-40A
A • 8
4.5 kA
E90E
Char. B
2-40A
A • 9
Char. C
2-40A
A • 9
6 kA
E90
Char. B
6-63A
A • 10
Char. C
0.5-63A
A • 10
Char. D
0.5-63A
A • 10
10 kA
E90S
Char. B
6-63A
A • 12
Char. C
0.5-63A
A • 12
Char. D
0.5-63A
A • 12
6 kA
E880
Char. B
80-125A
A • 14
Char. C
80-125A
A • 14
Char. D
80-125A
A • 14
10 kA
E880S
Char. B
80-125A
A • 15
Char. C
80-125A
A • 15
Char. D
80-125A
A • 15
25 kA
E90X
3-5 In
6-63A
A • 16
5-10 In
0.5-63A
A • 16
10-20 In
0.5-32A
A • 16
AC/DC mini. circuit breakers
6 kA
E90SUC
Char. B
6-63A
A • 17
Char. C
0.5-63 A
A • 17
Selective main miniature circuit
breakers
25 kA, single pole switching
S90
Char. CS
20-100A
A • 18
Char. E
10-100A
A • 18
Char. F
10-100A
A • 18
25kA, all-pole switching
S90
Char. CS
20-100A
A • 19
A • 20
Add-on auxiliary contacts
Accessories
A • 21
A • 1
962984281.010.png 962984281.011.png 962984281.012.png 962984281.013.png 962984281.014.png 962984281.015.png 962984281.016.png 962984281.017.png 962984281.018.png 962984281.019.png
A
Miniature circuit breakers
Five good reasons to appreciate
the AEG miniature circuit breakers
- Line protection
- People protection
1. Total protection
AEG Low Voltage MCB’s provide the best answer to the obligation of circuit protection.
They give comprehensive protection to circuits against:
– Overload currents (0.5A to 125A)
– Short-circuit currents (3000 up to 50000 A)
– Earth fault currents (30mA up to 1000mA) - combined with RCD’s
– The handle being sealable or equipped with padlock bracket avoids dangerous operation changes
(ON / OFF)
– The handle provides a clear indication of the contact position
– Top and bottom protection caps give save installation facilities
– Sealing accessories for top and bottom connections allow protection of original wiring
– Adequate printing of all data on the front provides long-term identification
2. Total quality
– The MCB’s are able to accomplish the line protection for more than 10,000 times, by a simple
manual, or motor operated reset
– The quality of the shells can cope with the hardest ambient circumstances (-25 ° C to +55 ° C)
– All MCB’s are current limiting MCB’s, the let-through energy being reduced far below
the standard limits. Energy limiting class: 3
– The low let-through peak-currents ensure the long life-time of the contacts of isolators or
loadbreak switches upstream
– The emission of ionised gases are limited to the severest restrictions (35 mm grid distance)
3. A wide range
AEG Low Voltage offers:
– MCB’s for household in accordance with:
IEC 898 - B, C and D tripping characteristics
– MCB’s for industry in accordance with:
IEC 947-2 - instantaneous tripping 3-5 In, 5-10 In, 10-20 In
– RCD’s in accordance with: IEC 1009 - BS 4293
4. Stock reducing system
The residential and industrial markets are covered by five appropriate series of MCB’s: Series E.
Their external advantages allow the consumer to extend the MCB at any time with:
–A wide range of RCD’s / people protection
– Five types of display contacts
– Shunt trip releases
– Accessories
5. Time saving connections
Insulated or non insulated busbar systems with maximum connection possibilities,
can be very fast put on the top or bottom terminals of the MCB’s.
A • 2
962984281.020.png 962984281.021.png 962984281.022.png 962984281.023.png 962984281.024.png 962984281.025.png 962984281.026.png 962984281.027.png 962984281.028.png 962984281.029.png 962984281.030.png 962984281.031.png 962984281.032.png 962984281.033.png 962984281.034.png 962984281.035.png 962984281.036.png 962984281.037.png 962984281.038.png
Miniature circuit breakers
Miniature circuit breakers
A
Benefits of the new MCB’s Series E90
Safety terminal:
–easy wiring
–no wrong fixing
Pozidriv and slot screw head.
Torque up to 4.5 N.m
Incoming/outgoing terminal capacity up to 35 mm 2
or 2 x 16 mm 2
protection degree IP20
Terminal side for fork busbar is isolated between
the poles.
Two positions of the DIN-rail clip.
Easy installation.
MCB's and RCCB's can be connected with PIN
type busbar at the top terminals.
MCB's and RCCB's can be connected with PIN
type busbar at the bottom terminals, with easy
DIN-rail extraction.
MCB's and RCCB's can be connected with FORK
type busbar at the bottom terminals, with easy
DIN-rail extraction.
Auxiliary contacts can be added on the left hand
side of the MCB.
A • 3
962984281.039.png 962984281.040.png 962984281.041.png 962984281.042.png 962984281.043.png 962984281.044.png 962984281.045.png 962984281.046.png 962984281.047.png 962984281.048.png 962984281.049.png 962984281.051.png 962984281.052.png 962984281.053.png 962984281.054.png 962984281.055.png 962984281.056.png 962984281.057.png 962984281.058.png 962984281.059.png 962984281.060.png 962984281.062.png 962984281.063.png 962984281.064.png 962984281.065.png 962984281.066.png
Zgłoś jeśli naruszono regulamin