MS_CHK_SSAS.pdf

(108 KB) Pobierz
692192582 UNPDF
Checklist for Survey of Ship Security Alert System (SSAS)
Ref. No.
Date
M/V
Class No
Type of Ship
IMO No.
Description of SSAS
(Manufacture)
(Type and serial No.)
Office:
Port:
Company of ship
Maritime Security Auditor:
Tick in the left box of following with if the item is checked with satisfaction; (for an audit subsequent to the initial
installation verification, item indicated "D" may be dispensed, in such a case, tick the box "D" to indicate dispensation)
1. General
1-1
D
Ship Security Alert System is complies with IMO Res.694(17) and/or IEC60945.
2. Power supply
2.1
D
Where the ship security alert system is powered from ship's main source of electrical power, it is possible
to operate the system from alternative source of power.
2-2
D
Alternative source of power is either emergency power supply, a storage battery charged with emergency
power source, or independent battery.
3. Operation
3-1
Ship Security Alert System is capable of being activated from the navigation bridge and in at least one
other location.
3-2
Ship Security Alert Messages addresses to competent authorities designated by the Administration.
3-3
Ship Security Alert System activation points is designed so as to prevent the inadvertent initiation of the
ship security alert. It is not necessary for the user to remove seals or to break any lid or cover in order to
operate any control.
3-4
D
The activation points operates a radio system such transmission of the security alert does not require any
adjustment of the radio system, i.e. tuning of channels, setting of modes or menu options.
3-5
D
Once activated, Ship Security Alert System continues to transmit the security alert until it is reset or
deactivated. The interval between transmissions of the alerts is as short as possible. (e.g. between 15
minutes and one hour)
3-6
D
Operation of the activation point does not cause any alarm or indication to be raised on the ship nor alert
other ships.
3-7
D
The operation of the ship security alert system does not impair the functionality of the GMDSS installation.
4. Ship Security Alert
Transmission initiated by security alert system activation points includes a unique code/identifier 1 (ship’s
identity, e.g. ship's name, call sign, IMO ship identification number or Maritime Mobile Service Identify
(MMSI)) and ship’s security alert activation indication.
4-1
4-2
The transmission includes the ship identity and current position (latitude and longitude) associated with a
date and time.
4-3
Ship Security Alert Messages (Ship’s identity, ship’s position and ship’s security alert activation indication)
are generated automatically with no input from the operator other than security alert system activation.
5. Installation
5-1
General inspection
5-2
D
Wiring (power cable and antenna cable) has been permanently installed.
5-3
Operational test
6. Others
6-1
D
The Ship Security Alert System is capable of being tested.
6-2 Operation manual and maintenance manual provided by manufacturer are placed onboard.
The undersigned certifies the status as given above and declares that all information known by the auditor or Radio Inspector relating to the SSAS
during this audit shall be treated with the strictest confidence and shall not be revealed to anyone without the written consent of the Company.
_________________________
__________________________
Radio inspector
Maritime Security Auditor to
Company
Nippon Kaiji Kyokai
1 The administration may instruct a unique code/identifier other than ship’s identity in the brackets.
Form MS-CHK-SSAS (2005.9.1)
692192582.001.png 692192582.002.png 692192582.003.png