Arc Fault Protection
System D1000
• Improve personnel safety
• Reduce damage
• Avoid costly repairs
• Minimize production downtime
www.selco.com
Segments & applications
In all areas where electrical energy is
distributed the D1000 Arc Fault Protec-
tion System is the choice to ensure the
highest possible personal and opera-
tional safety.
Typical areas where the results of an arc
fault can be fatal are within the follow-
ing segments:
• Industry
• Power generation
• Marine
• Wind Power
• Offshore
• Infrastructure
Within arc fault protection it is impor-
tant to protect the vital parts in the
switchgear and power distribution
boards. The part of the installation
where arc faults are likely to occur is
around:
• Bus bars and bus bar connections
• Circuit breakers
• Transformers
Beneits from D1000 Arc Protection
D1000 improves personnel safety
- Serious injuries to personnel can be avoided. Extreme heat, ire and pressure can be
fatal results of an arc fault. D1000 helps minimizing this risk and improves safety.
D1000 reduces damage to material
- Switchgear equipment and electrical installations are valuable assets. D1000 can
minimize or even avoid severe damage to costly equipment, and allow a fast and
safe power restoration.
D1000 minimizes production downtime
- The result of a sudden stop and downtime in the power supply can be expen-
sive for any operation. A quick reaction from the D1000 can reduce the production
downtime to a minimum or even avoid it.
D1000 enables better insurance conditions
- Insurance companies have seen the beneits of arc fault protection as a requirement.
Some insurance companies are even willing to offer better conditions, when an ef-
icient arc protection system like D1000 is installed to protect the electrical installation.
Arc Fault Protection
Eficient protection of high, medium and low voltage switchgear
A continuous supply of power is important in modern energy infrastructure and
most production facilities. Wherever electrical energy is generated and distributed,
arc lash faults and accidents are likely to occur. An arc protection system is an ef-
icient way to maximize safety and minimize damages.
SELCO’s D1000 Arc Protection System is designed to dramatically reduce the effects
of arc lash faults in high, medium and low voltage switchgear.
Fast protection is essential
An arc fault in a switchboard or control gear develops within milliseconds and lead
to the discharge of enormous amounts of energy between phase bus bars. If the arc
lash is allowed to develop the result is that massive energy discharge burns the bus
bars, vaporizing the copper and thus causing an explosion. Finally this may cause
extensive material damage and jeopardize the safety of operational personnel.
An arc protection system operates much faster than conventional protection relays
and thus damages caused by an arc lash fault can be kept at a minimum level. As a
general guideline, an arc will not cause any damage if it is eliminated within 35ms.
If the arc is allowed to continue and last 100ms some damage will occur. An arc fault
lasting 500ms may cause severe damage to the installation and will require exten-
sive repair.
A short arc time is crucial in order to avoid damage to personnel and material. It is
therefore of vital importance that the source leading to the arc lash time is mini-
mized and the power is disconnected as fast as possible.
SELCO’s D1000 Arc Protection System is the solution.
D1000 Functionality
The D1000 is an advanced and fast arc protection system, offering the following features:
• Compact unit - arc fault and overcurrent protection
• High speed arc fault detection less than 1ms
• Overcurrent protection with detection within 1ms
• Combines optical ibre and point sensors
• Real-time event logging
• Self-supervision of sensors and protection unit
• Easy installation and coniguration via USB
D1000 is the solution
Extended coverage with
the Link Input
The D1000 Protection system is easy
expandable.
Built-in overcurrent protection
D1000 integrates 3-phase current mea-
surement which can detect short- and
overcurrent and reacts within 1 ms. This
makes it possible to reduce unintended
tripping from e.g. lightning lashes or
welding without the traditional extra de-
lay and expense of an external overcur-
rent relay. The overcurrent function can
also be used to trip the breaker in case of
short circuits or long-lasting overloads
without arching.
D1000 Arc lash protection unit
The D1000 is a stand-alone and high
speed arc protection unit for electri-
cal power distribution systems. D1000
supports both point and ibre sensor
technologies for arc lash detection and
supports up to six sensors. The sensors
can be combined in any combinations,
depending on the application and
requirements.
With the Link Input up to 24 sensor
inputs is obtained by connecting up
to four D1000 units together. Alterna-
tively, the link feature can be used for
RS485 MODBUS RTU communication
(SCADA), and thereby easily integrated
into an external monitoring and control
system.
In case of an arc lash fault, the D1000
unit detects and generates a tripping
pulse in less than 1 ms, to the circuit
breaker(s) supplying the installation.
The total arcing time is thus reduced
to the mechanical opening time of the
circuit breaker, which is typical around
50-75 ms. The trip circuit is based on a
solid state switch, providing fast reac-
tion and drive capability for even the
largest circuit breakers.
Real-time event logging
The built-in USB connection provides
easy access to a real-time event log,
which gives detailed diagnostic informa-
tion about all events, incl. near misses
and daily operation events (e.g. conigu-
ration changes, test, reset, and power
cycling). This functionality improves
and increases switchgear life-cycle
expectancy.
Eficient self-supervision
The D1000 system provides continu-
ous surveillance of the complete system
including the connected sensors. Any
system faults, e.g. a sensor cable fault is
indicated by a lashing online LED and
is logged and reported.
The D1000 unit is equipped with easy
accessible select buttons; MODE, TRIP
and RESET which makes it easy to
switch between operation and service
mode, and is used to test the trip output
and conigure the connected sensors.
The D1000 unit can be powered from
either a DC or AC source. If the unit
is powered from AC, it can charge a
backup battery, which can drive the trip
circuit with 24VDC.
Easy coniguration
The D1000 is easy to install and set up
and in case any changes are needed
this is easily done via the USB interface
accessible from the front. The built-in
user-friendly menu system is embedded
in the D1000 unit and activates auto-
matically when the unit is connected to
a PC.
The built-in light sensor on the front
makes it easy to adjust and verify that
all sensors are correctly installed and
equally sensitive. With the TRIP LEVEL
adjustment on the front plate the sensi-
tivity to light can be adjusted. The light
range is 10.000-25.000 lux enabling use
of sensors under different light condi-
tions, indoor light, sunlight, etc.
Flexible and eficient sensors
A1000 point sensor
A2000 ibre sensor
Easy installation
The D1000 system is easy to install and
made to implement in new switchgear
installations as well as retroit projects.
Both the D1000 unit and sensors are
quick and easy to install. A general
guideline is to mount 1-2 sensors per
cubicle or chamber. It is important to
cover all horizontal/vertical busbars (1)
as well as breaker compartments (2) and
drawers.
A1000 point sensor
The point sensor is a light-sensitive ele-
ment based on phototransistor techno-
logy. It detects visible light radiation
which is captured at the cylindrical top.
The A1000 point sensor has a detection
area of up to 2 meter with a character-
istic of 180 x 360°. The A1000 supports
self supervision, and a clear lashing
built-in LED indicates that the sensor is
active. If the sensor reaches the trigger
level the LED will light up constantly.
The A1000 sensor is supplied with a 10m
shielded cable.
In small installations, the calibration
TEST sensor can be used as a single arc
detecting sensor, providing additional
protection without added cost. Setup of
the overcurrent detection is easily done
through the USB interface.
Example is shown below:
A2000 ibre sensor
The A2000 ibre sensor is a light sensi-
tive element based on optical ibre tech-
nology. The A2000 ibre sensor is a fully
lexible ibre with a detection angle of
360° throughout the length of the ibre.
The detection radius is up to 2 meter.
The A2000 ibre has 8 meter active cable
length sensitive to light. The ibre sensor
is ideal to install in electrical cabinets
with drawer sections.
Plik z chomika:
pilot1216
Inne pliki z tego folderu:
Introduction Gencontroller C6200.pdf
(226 KB)
D1000 Switchboard Application.pdf
(133 KB)
D1000 ochrona przed skutkami łuku elektrycznego.pdf
(2729 KB)
D1000 Arc Fault Protection System.pdf
(1198 KB)
D1000 Arc Detection Relay.pdf
(1584 KB)
Inne foldery tego chomika:
- II w.św. - Pacyfik, Azja
- II w.św. - Rosja - ZSRR
- II w.św. Afryka, Atlantyk
- ★ Oszukać Umysł
ENCYKLOPEDIA KOŚCIELNA
Zgłoś jeśli
naruszono regulamin