OPC_e.pdf
(
1956 KB
)
Pobierz
SIMATIC NET
Introduction to the OPC Server for SIMATIC NET
Manual
1
Overview of the OPC Server for SIMATIC NET
2
Quick Start
3
Basics of OLE
4
Basics of OPC
5
Structure of the OPC Items for the SIMATIC NET Data Access Interface
6
Properties of the OPC Event Server for SIMATIC NET
7
Configuration of the OPC Server for SIMATIC NET
8
Configuration Using Files
9
DCOM with the OPC-Server for SIMATIC NET
10
The OPC Custom Interface
for Data Access
11
The OPC Automation Interface
for Data Access
12
The OPC Custom Interface for Alarms & Events
13
Where to Get Help
14
Glossary
A
SIMATIC Computing
6GK1971-0BA00-0AA1
Release 3
SIMATIC NET is a trademark of Siemens
Siemens Aktiengesellschaft
Wir haben den Inhalt der Druckschrift auf
Übereinstimmung mit der beschriebenen Hard- und
Software geprüft. Dennoch können Abweichungen
nicht ausgeschlossen werden, so daß wir für die
vollständige Übereinstimmung keine Gewähr
übernehmen. Die Angaben in der Druckschrift
werden jedoch regelmäßig überprüft. Notwendige
Korrekturen sind in den nachfolgenden Auflagen
enthalten. Für Verbesserungsvorschläge sind wir
dankbar.
Technische Änderungen vorbehalten.
Weitergabe sowie Vervielfältigung dieser Unterlage,
Verwertung und Mitteilung ihres Inhalts nicht gestattet,
soweit nicht ausdrücklich zugestanden.
Zuwiderhandlungen verpflichten zu Schadenersatz.
Alle Rechte vorbehalten, insbesondere für den Fall
der Patenterteilung oder GM-Eintragung.
6GK1971-0BA00-0AA1
Copyright © Siemens AG 1997
All Rights Reserved
We have checked the contents of this manual for
agreement with the hardware described. Since
deviations cannot be precluded entirely, we cannot
guarantee full agreement. However, the data in this
manual are reviewed regularly and any necessary
corrections included in subsequent editions.
Suggestions for improvement are welcome.
Technical data subject to change.
The reproduction, transmission or use of this
document or its contents is not permitted without
express written authority. Offenders will be liable for
damages. All rights, including rights created by patent
grant or registration of a utility or design, are reserved.
6GK1971-0BA00-0AA1
Copyright © Siemens AG 1997
All Rights Reserved
Nous avons vérifié la conformité du contenu du
présent manuel avec le matériel et le logiciel qui y
sont décrits. Or, des divergences n'étant pas
exclues, nous ne pouvons pas nous porter garants
pour la conformité intégrale. Si l'usage du manuel
devait révéler des erreurs, nous en tiendrons compte
et apporterons les corrections nécessaires dès la
prochaine édition. Veuillez nous faire part de vos
suggestions.
Toute communication ou reproduction de ce support
d'informations, toute exploitation ou communication de
son contenu sont interdites, sauf autorisation
expresse. Tout manquement à cette règle est illicite et
expose son auteur au versement de dommages et
intérêts. Tous nos droits sont réservés, notamment
pour le cas de la délivrance d'un brevet ou celui de
l'enregistrement d'un modèle d'utilité.
6GK1971-0BA00-0AA1
Copyright © Siemens AG 1997
All Rights Reserved
Nous nous réservons le droit de modifier les
caractéristiques techniques.
Siemens Aktiengesellschaft
Elektronikwerk Karlsruhe
Printed in the Federal Republic of Germany
SIMATIC NET
Introduction to the OPC Server for SIMATIC NET
Manual
C79000-B8976-C126/3
Note
We would point out that the contents of this product documentation shall not become a part of or modify any prior or
existing agreement, commitment or legal relationship. The Purchase Agreement contains the complete and exclusive
obligations of Siemens. Any statements contained in this documentation do not create new warranties or restrict the
existing warranty.
We would further point out that, for reasons of clarity, these operating instructions cannot deal with every possible problem
arising from the use of this device. Should you require further information or if any special problems arise which are not
sufficiently dealt with in the operating instructions, please contact your local Siemens representative.
General
This device is electrically operated. In operation, certain parts of this device carry a dangerously high
voltage.
WARNING !
Failure to heed warnings may result in serious physical injury and/or material damage.
!
Only appropriately qualified personnel may operate this equipment or work in its vicinity. Personnel
must be thoroughly familiar with all warnings and maintenance measures in accordance with these
operating instructions.
Correct and safe operation of this equipment requires proper transport, storage and assembly as well
as careful operator control and maintenance.
Personnel qualification requirements
Qualified personnel as referred to in the operating instructions or in the warning notes are defined as persons who are
familiar with the installation, assembly, startup and operation of this product and who possess the relevant qualifications for
their work, e.g.:
Training in or authorization for connecting up, grounding or labeling circuits and devices or systems in accordance with
current standards in safety technology;
-
-
Training in or authorization for the maintenance and use of suitable safety equipment in accordance with current
standards in safety technology;
-
First Aid qualification.
Siemens Aktiengesellschaft
Elektronikwerk Karlsruhe
Printed in the Federal Republic of Germany
Contents
Contents
1
Overview of the OPC Server for SIMATIC NET......................................................
.13
1.1
OPC Interface...............................................................................................
.14
1.2
OPC Server, OPC Server for SIMATIC NET.................................................
.16
1.3
Advantages of the OPC Server.....................................................................
.18
1.4
Background Knowledge.................................................................................
.19
1.5
Guide to the Documentation..........................................................................
.20
2
Quick Start...............................................................................................................
.21
2.1 Installing and Starting up the Underlying Communications System................
.22
2.1.1 Installing the DP Protocol..............................................................................
.23
2.1.2 Installing the S7 Protocol...............................................................................
.24
2.1.3 Starting Up the S7 Protocol for Alarms & Events...........................................
.25
2.1.4 Installing the FMS Protocol............................................................................
.26
2.1.5 Installing the Send/Receive Protocol for Industrial Ethernet...........................
.28
2.1.6 Installing the Send/Receive Protocol for PROFIBUS (FDL)...........................
.30
2.1.7 Commissioning the DP Slave........................................................................
.32
2.2 Simulation Connections of the OPC Server...................................................
.33
2.2.1 Working with the Simulation Connection........................................................
.34
2.3
Description of the Quick Start........................................................................
.35
2.4
Using the Quick Start.....................................................................................
.36
3
Basics of OLE..........................................................................................................
.39
3.1
COM as the Basis for OPC............................................................................
.40
3.2
Objects and Interfaces...................................................................................
.41
3.3
Standard Representation of Objects in OLE..................................................
.43
3.4
Object Control Via the Automation Interface..................................................
.44
4
Basics of OPC..........................................................................................................
.45
4.1
The Role of OLE in OPC...............................................................................
.46
4.2
The OPC Specifications................................................................................
.47
4.3
The Two Interfaces of OPC...........................................................................
.48
4.4
The Class Model of OPC Data Access...........................................................
.50
4.5
The Principle of OPC Alarms & Events..........................................................
.52
4.6
Group Operations..........................................................................................
.55
4.7
The Client-Server Architecture of OPC..........................................................
.56
4.8
Terminology of the OPC Interface Description...............................................
.58
5
Structure of the OPC Items for the SIMATIC NET Data Access Interface.............
.63
Introduction to the OPC Server for SIMATIC NET
6GK1971-0BA00-0AA1
5
Plik z chomika:
masterkom
Inne pliki z tego folderu:
ET200iS_e.pdf
(22821 KB)
DOC_AS_PL_S7300_HW_moduly.pdf
(7881 KB)
DPPA_E.PDF
(4575 KB)
dyn_funktion_e.pdf
(4571 KB)
Cpu210_e.pdf
(1429 KB)
Inne foldery tego chomika:
Autoryzacja
Kable
Logo
OP Panels
S5
Zgłoś jeśli
naruszono regulamin