bta12xx.pdf

(106 KB) Pobierz
12A TRIACS
®
BTA/BTB12 and T12 Series
SNUBBERLESS™, LOGIC LEVEL & STANDARD
12A TRIAC S
MAIN FEATURES:
A2
Symbol
Value
Unit
I T(RMS)
12
A
G
A1
V DRM /V RRM
600 and 800
V
A2
I GT (Q 1 )
10 to 50
mA
A1
A2
DESCRIPTION
Available either in through-hole or surface-mount
packages, the BTA/BTB12 and T12 triac series is
suitable for general purpose AC switching. They
can be used as an ON/OFF function in
applications such as static relays, heating
regulation, induction motor starting circuits... or for
phase control operation in light dimmers, motor
speed controllers,...
The snubberless versions (BTA/BTB...W and T12
series) are specially recommended for use on
inductive loads, thanks to their high commutation
performances. By using an internal ceramic pad,
the BTA series provides voltage insulated tab
(rated at 2500V RMS) complying with UL
standards (File ref.: E81734)
G
D 2 PAK
(T12-G)
A2
A1
A1
A2
G
A2
G
TO-220AB Insulated
(BTA12)
TO-220AB
(BTB12)
ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
Value
Unit
I T(RMS)
RMS on-state current (full sine wave)
D ² PAK/TO-220AB Tc = 105°C
12
A
TO-220AB Ins.
Tc = 90°C
I TSM
Non repetitive surge peak on-state
current (full cycle, Tj initial = 25°C)
F = 50 Hz
t = 20 ms
120
A
F = 60 Hz
t = 16.7 ms
126
I ² t
I ² t Value for fusing
tp = 10 ms
100
A ² s
dI/dt
Critical rate of rise of on-state current
I G = 2 x I GT , tr
£
100 ns
F = 120 Hz
Tj = 125°C
50
A/µs
V DSM /V RSM
Non repetitive surge peak off-state
voltage
tp = 10 ms
Tj = 25°C
V DRM /V RRM
+ 100
V
I GM
Peak gate current
tp = 20 µs
Tj = 125°C
4
A
P G(AV)
Average gate power dissipation
Tj = 125°C
1
W
T stg
T j
Storage junction temperature range
Operating junction temperature range
- 40 to + 150
- 40 to + 125
°C
September 2000 - Ed: 3
1/7
199620489.007.png
BTA/BTB12 and T12 Series
ELECTRICAL CHARACTERISTICS (Tj = 25°C, unless otherwise specified)
n
SNUBBERLESS™ and LOGIC LEVEL (3 Quadrants)
Symbol
Test Conditions
Quadrant
T12
BTA/BTB12
Unit
T1235
SW
CW
BW
I GT (1)
V D = 12 V R L = 30
W
I - II - III
MAX.
35
10
35
50
mA
V GT
I - II - III
MAX.
1.3
V
V GD
V D = V DRM R L = 3.3 k
W
I - II - III
MIN.
0.2
V
Tj = 125°C
I H (2)
I T = 100 mA
MAX.
35
15
35
50
mA
I L
I G = 1.2 I GT
I - III
MAX.
50
25
50
70
mA
II
60
30
60
80
dV/dt (2) V D = 67 %V DRM gate open
Tj = 125°C
MIN.
500
40
500
1000
V/µs
(dI/dt)c (2) (dV/dt)c = 0.1 V/µs Tj = 125°C
MIN.
-
6.5
-
-
A/ms
(dV/dt)c = 10 V/µs Tj = 125°C
-
2.9
-
-
Without snubber Tj = 125°C
6.5
-
6.5
12
n
STANDARD (4 Quadrants)
Symbol
Test Conditions
Quadrant
BTA/BTB06
Unit
C
B
I GT (1)
I - II - III
IV
MAX.
25
50
50
100
mA
V D = 12 V R L = 30
W
V GT
ALL
MAX.
1.3
V
V GD
V D = V DRM R L = 3.3 k
W
Tj = 125°C
ALL
MIN.
0.2
V
I H (2)
I T = 500 mA
MAX.
25
50
mA
I L
I G = 1.2 I GT
I - III - IV
MAX.
40
50
mA
II
80
100
dV/dt (2) V D = 67 %V DRM gate open Tj = 125°C
MIN.
200
400
V/µs
(dV/dt)c (2) (dI/dt)c = 5.3 A/ms Tj = 125°C
MIN.
5
10
V/µs
STATIC CHARACTERISTICS
Symbol
Test Conditions
Value
Unit
V T (2)
I TM = 17 A tp = 380 µs
Tj = 25°C
MAX.
1.55
V
V to (2)
Threshold voltage
Tj = 125°C
MAX.
0.85
V
R d (2)
Dynamic resistance
Tj = 125°C
MAX.
35
m
W
I DRM
I RRM
V DRM = V RRM
Tj = 25°C
5
µA
MAX.
Tj = 125°C
1
mA
Note 1: minimum IGT is guaranted at 5% of IGT max.
Note 2: for both polarities of A2 referenced to A1
2/7
199620489.008.png 199620489.009.png
BTA/BTB12 and T12 Series
THERMAL RESISTANCES
Symbol
Parameter
Value
Unit
R th(j-c)
Junction to case (AC)
D ² PAK/TO-220AB
1.4
°C/W
TO-220AB Insulated
2.3
R th(j-a)
Junction to ambient
S = 1 cm ²
D ² PA K
45
°C/W
TO-220AB
TO-220AB Insulated
60
S = Copper surface under tab
PRODUCT SELECTOR
Part Number
Voltage (xxx)
Sensitivity
Type
Package
600 V
800 V
BTA/BTB12-xxxB
X
X
50 mA
Standard
TO-220AB
BTA/BTB12-xxxBW
X
X
50 mA
Snubberless
TO-220AB
BTA/BTB12-xxxC
X
X
25 mA
Standard
TO-220AB
BTA/BTB12-xxxCW
X
X
35 mA
Snubberless
TO-220AB
BTA/BTB12-xxxSW
X
X
10 mA
Logic level
TO-220AB
T1235-xxxG
X
X
35 mA
Snubberless
D ² PA K
BTB: non insulated TO-220AB package
ORDERING INFORMATION
BT A 12 - 600 BW
TRIAC
SERIES
INSULATION:
A: insulated
B: non insulated
VOLTAGE:
600: 600V
800: 800V
SENSITIVITY & TYPE
B: 50mA STANDARD
BW: 50mA SNUBBERLESS
C: 25mA STANDARD
CW: 35mA SNUBBERLESS
SW: 10mA LOGIC LEVEL
CURRENT: 12A
T 12 35 - 600 G (-TR)
TRIAC
SERIES
PACKAGE:
G: D PAK
CURRENT: 12A
2
VOLTAGE:
600: 600V
800: 800V
PACKING MODE:
Blank: Tube
-TR: Tape & Reel
SENSITIVITY:
35: 35mA
3/7
199620489.010.png 199620489.001.png
BTA/BTB12 and T12 Series
OTHER INFORMATION
Part Number
Marking
Weight
Base
quantity
Packing
mode
BTA/BTB12-xxxyz
BTA/BTB12-xxxyz
2.3 g
250
Bulk
T1235-xxxG
T1235xxxG
1.5 g
50
Tube
T1235-xxxG-TR
T1235xxxG
1.5 g
1000
Tape & reel
Note: xxx = voltage, yy = sensitivity, z = type
Fig. 1: Maximum power dissipation versus RMS
on-state current (full cycle).
Fig. 2-1: RMS on-state current versus case
temperature (full cycle).
P (W)
IT(RMS) (A)
6
14
1 13
4
BTB/T12
2
11
BTA
0
9
8
8
7
6
5
4
3
2
IT(RMS)(A)
2
Tc(°C)
0
0
0123456789012
0
25
50
75
100
125
Fig. 2-2: RMS on-state current versus ambient
temperature (printed circuit board FR4, copper
thickness: 35µm),full cycle.
Fig. 3: Relative variation of thermal impedance
versus pulse duration.
IT(RMS) (A)
K=[Zth/Rth]
3.5
1E+0
DPAK
(S=1cm )
2
3.0
2
Zth(j-c)
2.5
2.0
1E-1
Zth(j-a)
1.5
1.0
0.5
Tamb(°C)
tp(s)
0.0
0
25
50
75
100
125
1E-2
1E-3
1E-2
1E-1
1E+0
1E+1
1E+2 5E+2
4/7
10
199620489.002.png 199620489.003.png 199620489.004.png
BTA/BTB12 and T12 Series
Fig. 4: On-state characteristics (maximum
values).
Fig. 5: Surge peak on-state current versus
number of cycles.
ITM (A)
ITSM (A)
100
130
120
110
t=20ms
100
Tj max
90
Non repetitive
Tj initial=25°C
One cycle
80
70
10
60
Tj=25°C
50
Repetitive
Tc=90°C
40
Tj max.
Vto = 0.85 V
Rd = 35 m
30
20
W
VTM(V)
10
Number of cycles
1
0
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
1
10
100
1000
Fig. 6: Non-repetitive surge peak on-state
current for a sinusoidal pulse with width
tp < 10ms, and corresponding value of I²t.
Fig. 7: Relative variation of gate trigger current,
holding current and latching current versus
junction temperature (typical values).
ITSM (A), I²t (A²s)
IGT,IH,IL[Tj] / IGT,IH,IL [Tj=25°C]
Tj initial=25°C
2.5
1000
dI/dt limitation:
50A/µs
2.0
ITSM
IGT
1.5
I²t
100
IH & IL
1.0
0.5
tp (ms)
Tj(°C)
10
0.01
0.10
1.00
10.00
0.0
-40 -20
0
20 40 60 80 100 120 140
Fig. 8: Relative variation of critical rate of
decrease of main current versus (dV/dt)c (typical
values).
Fig. 9: Relative variation of critical rate of
decrease of main current versus junction
temperature.
(dI/dt)c [(dV/dt)c] / Specified (dI/dt)c
(dI/dt)c [Tj] / (dI/dt)c [Tj specified]
2.8
6
2.4
SW
5
2.0
4
C
1.6
B
3
1.2
BW/CW/T1235
0.8
2
0.4
(dV/dt)c (V/µs)
1
Tj (°C)
0.0
0.1
1.0
10.0
100.0
0
0
25
50
75
100
125
5/7